Explore the equipment catalogue

Showing the first 40. Add a model name to narrow your search.

UA-Intercom · Perth installation

UniFi Access Intercom
Installation Perth.

Plan your UniFi Access Intercom installation in Perth with Servicewest. We assess the site and supporting equipment before specifying UA-Intercom.

  • Door or gate and existing hardware
  • Compatible hub, reader and network
  • Exit arrangements and operator permissions
Request a site assessment Australian model, compatibility and procurement checked before the scope is confirmed.

Installing Access Intercom. Start with the site.

Assess the opening for Access Intercom.

Installing UA-Intercom starts with the door or gate, the people using it and the existing hardware. We check the intended function and the supported UniFi Access components before proposing a complete arrangement.

Installation details for UA-Intercom

Power Method: PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU. Max. Power Consumption: 13W. Networking Interface: (1) GbE RJ45 port. Mounting: Wall mount, adapter to the gooseneck pedestal (Included) Surface angle, flush mount, sunshield kit (Optional). Weatherproofing: IP65. These manufacturer figures inform the mounting, connection and site assessment; we check the final model and supporting equipment before installation.

Coordinate entry and normal exit.

Reader placement, controller location, cable routes and the interface to the door hardware must be considered together. We assess normal exit, the existing release arrangements and the responsibilities of the property operator. The product page is a planning reference, not a terminal wiring guide.

Agree the permissions and handover.

The scope records the required credentials, schedules, administrator roles and visitor functions supported by the selected system. We test the agreed sequence and explain how the operator manages routine access changes.

Know the
equipment.

Manufacturer specifications for UA-Intercom. Check the selected model, regional version and current software requirements during assessment.

View manufacturer source
At a glance
DisplayTouch Display
Physical UnlockKeypad Unlock
SoundTwo-Way Audio
WeatherproofOutdoor Exposed
Overview
Dimensions324.8 x 113.7 x 28.3 mm (12.8 x 4.5 x 1.1")
UniFi Application SuiteAccess
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
WeatherproofingIP65
Mechanical
WeightDevice: 965 g (2.1 lb) Bracket: 445 g (1 lb)
Enclosure MaterialAluminum alloy, UV-stabilized polycarbonate, glass
Mount MaterialPowder-coated stainless steel
MountingWall mount, adapter to the gooseneck pedestal (Included) Surface angle, flush mount, sunshield kit (Optional)
Hardware
Indoor and Outdoor UseYes
Networking Interface(1) GbE RJ45 port
ConnectivityBLE 4.2 NFC
Power MethodPoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. Power Consumption13W
Supported Voltage Range48V DC
Max. Frame Rate30 FPS
Resolution2MP 1200 x 1600 (3:4)
Resolution8 MP (2448 × 3264)
Field of ViewH: 79.4°, V: 97.5°, D: 118.2°
SensorsProximity sensor ALS sensor
Size177 mm (7") diagonal
Screen TechnologyCapacitive multi-touch
LuminanceMax. 1000 nits (Typical)
Screen OrientationPortrait
Resolution1024 x 600 px
NFC Frequency13.56 MHz
NFC Read Range< 30 mm (1.18'')
NFC TechnologyISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T
LEDsAmber Learn More
Buttons(1) Factory reset
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Intercom, V01
Ambient Operating TemperatureDevice: -30 to 60° C (-22 to 140° F) Display: -25 to 60° C (-13 to 140° F)The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v 1.0.66)
Ambient Operating Humidity5 to 90% noncondensing
Software
Management ApplicationAccess
Software InformationThe software version can be checked at https://unifi.ui.com

Plan the supporting equipment. Check the complete system.

Related catalogue items to discuss. Compatibility is checked against the exact model and site design.

A few practical questions.

Can you assess Access Intercom for an existing system?
Yes. Include UA-Intercom, your existing console or host equipment, and a brief description of the work in your enquiry. We check compatibility, capacity and site access before confirming the installation scope.
What should I send for a Access Intercom assessment?
Send your suburb, property type, the intended location and any existing equipment model numbers. Door or gate and existing hardware and compatible hub, reader and network are useful starting points. Photographs of the proposed location can help with the initial discussion.
Does this page confirm Australian stock or a fixed installation price?
No. This catalogue uses manufacturer product references. We confirm the suitable Australian model, procurement options and a site-specific scope before quoting.

Keep planning.

Let’s look at your site.

Good installations
start with a conversation.

Tell us your suburb, your property and what you want to connect. We’ll work through the equipment and the installation with you.